EPA issues Records of Decision (RODs) to explain which cleanup methods will be used at Superfund National Priorities List sites. EPA has two primary documents that it may use to identify changes to the remedies selected in RODs. EPA uses a ROD Amendment when it needs to make a fundamental change to the remedy. EPA publishes an Explanation of Significant Differences (ESD) for significant changes.

During cleanup, complex sites may be divided into several distinct areas to make the response more efficient. These areas, called operable units (OUs), may address geographic areas, specific problems, or medium (e.g., groundwater, soil) where a specific action is required.

EPA is working to improve data quality. The information presented on this page is undergoing review for accuracy and completeness, and may be subject to change.

OU ID Name Decision Document Cleanup Technologies Selected
in the Decision Document
00 SITEWIDE No decision document
01 LANDFILL 5 Record of Decision
September 27, 1993
Cap (engineered cap)
Cap (exsitu)
Consolidate (onsite)
Dewatering
Discharge (POTW)
Discharge (surface water/NPDES discharge)
Excavation
Extraction (recovery/vertical well)
Institutional Controls
Landfill Gas Collection/Treatment
Monitoring
Treatment (other, NOS, exsitu, onsite)
02 SITE 34 JETC Record of Decision
September 27, 1993
Carbon Adsorption (liquid phase, P&T, exsitu)
Dewatering
Discharge (surface water/NPDES discharge)
Disposal (offsite)
Excavation
Extraction (recovery/vertical well)
Filtration (P&T, exsitu)
Monitoring (ambient air)
Storage (temporary, onsite)
03 FIRE TRAINING AREA Record of Decision
September 30, 1994
Air Stripping (P&T, exsitu)
Cap (engineered cap)
Carbon Adsorption (liquid phase, P&T, exsitu)
Coagulation/Flocculation (P&T, exsitu)
Discharge (surface water/NPDES discharge)
Filtration (P&T, exsitu)
Monitoring
Oil Water Separation (P&T, exsitu)
Precipitation (P&T, exsitu)
Residuals Disposal
Soil Vapor Extraction (exsitu)
Storage (temporary, onsite)
Treatment (other, NOS, exsitu, onsite)
04 BUILDING 113, 119 Record of Decision
September 26, 1995
Air Stripping (P&T, exsitu)
Chemical Oxidation/Reduction (P&T, exsitu)
Discharge (surface water/NPDES discharge)
Disposal (offsite)
Excavation
Extraction (recovery/vertical well)
Filtration (P&T, exsitu)
Institutional Controls
Monitoring
Other (NOS)
Treatment (other, NOS, exsitu, onsite)
Vertical Engineered Barrier (other)
05 ZONE 1 Record of Decision
June 26, 1995
Institutional Controls
Monitored Natural Attenuation
Monitoring
06 ZONE 2 Record of Decision
September 18, 1995
Air Sparging (physical treatment, insitu)
Institutional Controls
Monitored Natural Attenuation
Monitoring
Soil Vapor Extraction (insitu)
07 ZONE 3 Record of Decision
September 26, 1995
Air Stripping (P&T, exsitu)
Carbon Adsorption (liquid phase, P&T, exsitu)
Discharge (surface water/NPDES discharge)
Disposal (offsite)
Excavation
Extraction (recovery/vertical well)
Filtration (P&T, exsitu)
Hydraulic Control (containment)
Institutional Controls
Monitored Natural Attenuation
Monitoring
No Further Action
Treatment (other, NOS, exsitu, onsite)
07 ZONE 3 Record of Decision Amendment
December 30, 2003
Air Stripping (P&T, exsitu)
Monitored Natural Attenuation
Monitoring
No Further Action
Permeable Reactive Barrier (chemical reactive wall, passive treatment wall, etc.)
Treatment (other, NOS, exsitu, onsite)
07 ZONE 3 Explanation of Significant Differences
December 10, 2012
Bioremediation (other, NOS, insitu)
07 ZONE 3 Explanation of Significant Differences
October 24, 2013
Bioremediation (anaerobic, insitu)
Bioremediation (bioaugmentation, insitu)
ESD/Amd - Significant Cleanup Time Change
08 ZONE 4 Record of Decision
January 30, 1995
Cap (engineered cap)
Carbon Adsorption (liquid phase, P&T, exsitu)
Consolidate (onsite)
Dewatering
Discharge (POTW)
Discharge (surface water/NPDES discharge)
Excavation
Filtration (P&T, exsitu)
Institutional Controls
Ion Exchange (P&T, exsitu)
Monitored Natural Attenuation
Monitoring
Wetlands Replacement
09 ZONE 5 Record of Decision
September 30, 1994
No Further Action
10 OLD JET ENGINE TEST STAND Record of Decision
August 09, 1995
Air Sparging (physical treatment, insitu)
Disposal (offsite)
Excavation
Institutional Controls
Monitoring
Soil Vapor Extraction (insitu)
11 CONSOLIDATED BROOKS/DITCHES Record of Decision
September 30, 1997
Data not available
12 SITE 49 No decision document