EPA Superfund Program: KEARSARGE METALLURGICAL CORP., CONWAY, NH

Superfund Site Profile

www.epa.gov/superfund/kearsarge

The 9-acre Kearsarge Metallurgical Corporation (KMC) is located in Conway, New Hampshire on the north shore of Pequawket Pond.  KMC made precision stainless steel castings on site from 1964 until the company went out of business in 1982.  The manufacturing process produced castings using the lost-wax process.  That process created waste casting sands, wax and solvents that KMC dumped in a wooded wetland just east of the facility.  Investigations conducted by the New Hampshire Department of Environmental Services (NHDES) and EPA after KMC ceased operations showed that in addition to a large pile of mixed casting sands and solvents, groundwater at the Site was contaminated with volatile organic compounds (VOCs), predominantly 1,1,1-trichloroethane (1,1,1-TCA), and its breakdown products, particularly 1,1-dichloroethene (1,1-DCE).

EPA investigated the Site and issued a cleanup decision in September 1990 splitting the remedy into two efforts: removing the surficial source materials, and then addressing the groundwater through a pump-and-treat remedy.  EPA completed the source control remedy in September 1992, removing 13,620 tons of waste pile material, 41.85 tons of crushed drums, a solvent-contaminated septic tank and 12 yards of contaminated septic soils. 

EPA built the groundwater treatment plant in 1993, and NHDES operated it until 2005.  The extraction system cleaned up all groundwater contaminated from the Site on the west side of Hobbs Street by 2003.  The east side, where the waste pile had lain, significant contamination remained in soils and groundwater.

To address these soil issues, EPA funded, and NHDES contracted, a soil excavation effort in the affected area.  From October through December 2003, NHDES contractors excavated, dewatered, and disposed of 5,670 tons of soils contaminated with chlorinated solvents from the east side.  NHDES then filled the excavated area with gravel and installed a new extraction well, EW-13B.  Pumping and treating of water from this area began in February 2004 and continued until December 2005.

In December 2005, EPA and NHDES agreed that contaminant concentrations had declined significantly in the culvert area and discontinued pumping to assess the potential for a rebound of contamination.  Ultimately, EPA and NHDES determined that contaminant concentrations were not abating. NHDES then designed and implemented a soil mixing / soil treatment remedy in fall 2015.

TOPICS IN FOCUS

Institutional controls are required for this site.
 
This site requires ICs because a decision document, such as a Record of Decision, has documented some level of contamination and/or remedy component at the site that would restrict use of the site. These ICs are required to help ensure the site is used in an appropriate way and that activities at the site do not damage the cleanup components. These ICs will remain in place for as long as the contamination and/or cleanup components stay on site. The matrix below is a general summary of the restrictions at this site at the date of this report. The information in this matrix is a general description of the restrictions at the site only. The site contacts should be consulted if there are questions on the ICs for this site.
 
The following IC Instruments provide media-specific use restrictions that have been implemented by EPA for protecting human health, the environment and remedial engineering on this site. Instruments are documents used by EPA or other organizations to implement the use restrictions at a site. To know about other media-specific use restrictions that are planned but not implemented at this site, please contact the Regional Office using the Site Contact listed above. Note that where multiple entries occur, it will impact more than one pathway.
 
Click here for IC Instruments implemented for this site. http://semspub.epa.gov/src/collection/01/SC31715

ICs are generally defined as administrative and legal tools that do not involve construction or physically changing the site. Common examples of ICs include site use and excavation restrictions put in place through State and local authorities like zoning, permits and easements. ICs are normally used when waste is left onsite and when there is a limit to the activities that can safely take place at the site (i.e., the site cannot support unlimited use and unrestricted exposure) and/or when cleanup components of the remedy remains onsite (e.g., landfill caps, pumping equipment or pipelines). Effective ICs help ensure that these sites can be returned to safe and beneficial use.
 
Disclaimer: This information is being provided by EPA as an informational tool to further assist the public in determining the types of restrictions that may be in place at National Priorities List sites being addressed by EPA under the Superfund program. In addition to the areas addressed by the institutional controls identified on this web site there may be other areas on the property that require restrictions on use of the property that are not captured in this EPA database. States and other entities may have implemented laws or restrictions applicable to this site. The information provided herein does not replace a title search or meet "All Appropriate Inquiry" requirements. U.S. EPA encourages users to review the Site files to obtain information regarding remedy components, containment systems and the land use for which cleanup standards were selected for these sites. More information and links can be found in the Institutional Control instrument collection of document, above, and the EPA regional offices may also be contacted.


SITE STATUS

Construction
Complete?
Yes (09/24/1993)
Human Exposure
Status

Under Control
Contaminated Ground
Water Status
Under Control
Site-Wide Ready for
Anticipated Use?
Yes